CE MARK advanced anesthesia machine ARIES 2500

CE MARK advanced anesthesia machine ARIES 2500
Product Detailed
1.Respiration mode: IPPV, VCV, PCV, SIMV, SIGH, MANUAL, STANDBY,DEMO 2.Waveform: P-t, F-t, V-t, F-v, V-p 3.Tidal Volume20~1600

advanced anesthesia machine  ARIES 2500

Special Feature

Display: 10.4 TFT color screen

Application: Adult, Pediatric

Driven mode: Pneumatically driven electronically controlled

Mode: Semi~open, Semi~closed or closed system

Anesthetic vaporizer: two high precise vaporizers, Halothane, Enflurane or Isoflurane

Power supply: 220V±10%, 50Hz±1Hz

10V±10%, 60Hz±1Hz

Internal battery: DC12V (over 4 working hours)

Fresh gas outlet is in front of frame

Anesthesia Ventilator

 

Respiration mode: IPPV, VCV, PCV, SIMV, SIGH, MANUAL, STANDBY, DEMO

Waveform: P-t, F-t, V-t, F-v, V-p

Tidal Volume: 20~1600ml

Respiratory frequency: 1~65bpm

I:E ratio: 8:1~1:8

Inspiration pause: 0~55%Ti

Inspiration Pressure: 1~60cmH2O

Trigger Pressure: -20~20cmH2O

Monitoring parameters: O2 concentration, MV, Respiratory frequency, Tidal volume, Ppeak, PEEP, I:E ratio, Pmean, etc..

Alarm parameters:

high pressure alarm, low pressure alarm, O2 concentration alarm, MV alarm, O2 source failure alarm, AC power failure alarm, etc.

Pressure alarm setting:

High pressure alarm set 1~60cmH2O.

Low pressure alarm set 0~20cmH2O

O2 concentration alarm setting:

high: 21~99%.

Low: 21~50%.

MV alarm setting:

MV high alarm set 10~99L/min

MV low alarm set 0~40L/min

Main Unit

 

Circle absorber: Compact circle absorber

Flow meter:

Five~tube flow meter

O2 tube: 0L/min~1L/min~10L/min.

N2O tube: 0L/min~1L/min~10L/min.

Air tube: 0L/min~10L/min

O2 and N2O Linkage Device, keep oxygen concentration over 25%

Oxygen flush: 25L/min~75L/min

Gas source pressure:

O2: 0.25Mpa~0.65MPa

N2O: 0.25Mpa~0.65MPa

Air: 0.25Mpa~0.65MPa

CE MARK advanced anesthesia machine ARIES 2500



Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.